4 Installing the BlueFox System
y Dispose of packaging materials in an environmentally acceptable manner.
y Read the Installation and operating instructions.
4.1 Installing and connecting the alarm box
Only an approved specialist may connect the electricity supply, connect the unit to
the mains and commission the alarm box.
4.1.1 Selecting a location for installation
When selecting a location for installation take into consideration:
The pool sensor must be installed approx. 50 cm beneath the water surface. See
Fitting the pool sensor, P. 16.
Wall outlet
Floor
Minimum 1.6 m
Minimum 2,0 m
Minimum distance between the
alarm box and wall outlet: 2 m
(see g.)
Minimum distance between the
oor and the alarm box: 1.6 m
(see g.)
The alarm box must be installed
out of the reach of children (see
warning Changing the PIN, page
25).
The alarm box must be within
reach of the operator.
Observe any country-specic regulations pertaining to the installation location.
Observe the local building regulations.
Observe the requirements of the local electricity supply utility.
In outdoor installations the alarm box must be covered and protected from direct
sunlight.
Option: Pool sensor cable extension (see Optional Accessories, P. 46)